Overall Summary of the Device
Explain the positioning of the device through its development history, overseas use, comparison with similar medical devices, and related information.
SUMMARY TECHNICAL DOCUMENTATION
STED (Summary Technical Documentation) is a document used to organize the technical information required for a medical device approval application in Japan in a form that is easy to review.
It is important to connect the application form, test reports, Essential Principles, risk management, clinical evaluation, labeling, and other materials through one consistent explanation.
A STED does more than describe the product overview. It clarifies which supporting documents substantiate the intended use, specifications, safety, performance, clinical evaluation, and other aspects of the application.
Related guide: Using CE Marking Documents for Japan Medical Device Applications
The required documents and the depth of explanation vary depending on the application category and product characteristics.
If the STED is prepared independently from the other application materials, inconsistencies with the application form or test reports can easily arise. It is therefore important to review the entire application package in parallel.
Explain the positioning of the device through its development history, overseas use, comparison with similar medical devices, and related information.
For each requirement of the Essential Principles, organize the applicable standards, evaluation methods, and supporting documents.
Describe the intended use, structure and principle of operation, specifications, accessories, method of use, and related information.
Provide documentation supporting the application content for performance, safety, biological safety, sterilization, stability, software, clinical evaluation, and other relevant areas.
Organize warnings, contraindications and prohibitions, precautions for use, and the rationale for establishing them.
Align manufacturing processes, manufacturing sites, sterilization, quality management, and related information with the application form and QMS documentation.
Confirm that the target patients and clinical purpose are consistent across the application form, STED, clinical evaluation, and labeling.
Confirm that the specifications, test methods, acceptance criteria, and test report results correspond to each other.
Confirm that the models, sizes, and accessories included in the application can be supported by the submitted test and clinical data.
Confirm that identified hazards, risk control measures, warnings, contraindications, and precautions for use correspond to each other.
Confirm that the manufacturing sites and processes described in the application form are consistent with the STED, QMS, sterilization, and other supporting documentation.
Ensure that the relevant sections of test reports and standards-conformity documentation can be traced from the STED.
Confirm whether the application is new, improved, or generic, the product characteristics, whether clinical study results are available, and other relevant factors.
Confirm the latest versions of test reports, risk management documents, clinical documents, standards-conformity documentation, manufacturing documents, and other supporting materials.
For each statement in the STED, identify the referenced document and the relevant section.
Confirm consistency with the application form for the intended use, product specifications, product configuration, manufacturing method, and other key items.
Confirm terminology, versions, and conclusions across the STED, test reports, Essential Principles documentation, risk management, clinical evaluation, labeling, and other materials.
Yes, but because the STED is closely related to the other application materials, consistency with the application form, test reports, and related documents must also be checked.
Some materials can be used. They should be mapped to the Japanese STED sections, and any missing explanations or Japan-specific requirements should be added.
Starting after the main application strategy and required testing have been organized makes it easier to identify inconsistencies among the documents at an early stage.
For official information on medical device submission documentation and review materials in Japan, refer to the following PMDA sources.
We support preparation of approval application materials, including the STED, and cross-check consistency with the application form, test documents, clinical evaluation, and related materials.
Approval, Certification & Notification Support